6-9
2000-800-02 Motorized Loader
Motorized Control Box
Fig 6-6 Front Control Panel.
Front Panel Membrane Function Keys
The MCB has a Liquid Crystal Display (LCD) which is mounted
on an attractive front panel.
ALL set-ups and control commands are easily entered via the
membrane Keys:
F1 To change / select the Mode.
F2 For Diagnostic only.
F3 Reserved.
F4 Reserved.
Cursor Keys: Up, Down, Left, Right
TO ENTER PARAMETERS. e.g., target torque limits, number
of cycles, motor, direction -- CW or CCW.
ENTER To accept the parameters.
RUN To run the selected mode.
STOP To stop the motor or Cancel the current setup.
MOTORIZED CONTROL BOX
EMERGENCY STOP
MADE IN U.S.A.
ON OFF
SYSTEM CONTROL
STOPRUN
F1
F3
F2
F4