SURETEST AND 600TL Model 5000-3 Torque Calibration System USER’S MANUAL

Strany 2 - TABLE OF CONTENTS

FUNCTIONAL DESCRIPTION AND SPECIFICATIONS CHAPTER 2 CHAPTER 2 Functional Description and Specifications The CDI 5000-3 is CDI’s next generation Tor

Strany 3

FUNCTIONAL DESCRIPTION AND SPECIFICATIONS CHAPTER 2 SURETEST BASE UNIT Front Panel Figure 2-2 SURETEST Front Panel A- Membrane Function

Strany 4 - Using this Manual

FUNCTIONAL DESCRIPTION AND SPECIFICATIONS CHAPTER 2 Display A 240 x 64 Full-featured Graphic LCD is used to provide versatile and clear displays of s

Strany 5 - CAUTION

FUNCTIONAL DESCRIPTION AND SPECIFICATIONS CHAPTER 2 The SURETEST returns to the default menu from the measurements mode in the event there is no selec

Strany 6 - Safety Information

FUNCTIONAL DESCRIPTION AND SPECIFICATIONS CHAPTER 2 3. Select Language Selects either English, German (Deutsch), French (François), Spanish (Español)

Strany 7

FUNCTIONAL DESCRIPTION AND SPECIFICATIONS CHAPTER 2 6. Edit Limits Sets up high torque limit preset. (-->) (F4) to go Down 1 line. Sets up low

Strany 8 - Introduction

FUNCTIONAL DESCRIPTION AND SPECIFICATIONS CHAPTER 2 9. Edit Parameters Sets up serial communications protocol. Sets delay (in ms) per character u

Strany 9

FUNCTIONAL DESCRIPTION AND SPECIFICATIONS CHAPTER 2 Sets up memory clear options in RECALL mode. Recalls memory data to display. Format (F3) calls S

Strany 10 - CHAPTER 2

FUNCTIONAL DESCRIPTION AND SPECIFICATIONS CHAPTER 2 SURETEST BASE UNIT Rear Panel (Input/Output) Figure 2-3 SURETEST Rear Panel A - Solenoid

Strany 11 - Front Panel

FUNCTIONAL DESCRIPTION AND SPECIFICATIONS CHAPTER 2 F- PRINTER PORT (DB-9P) PIN FUNCTION 2 Receive 3 Transmit 5 Ground G- OPTIONAL (DB-9P) PIN

Strany 12 - Power Up Sequence

TABLE OF CONTENTS Safety Information I Introduction 1-1 Functional Description and Specifications 2-1 Functional Descriptions

Strany 13 - Setup Mode

FUNCTIONAL DESCRIPTION AND SPECIFICATIONS CHAPTER 2 SURETEST Transducers SURETEST transducers provide industry standard square drives. They feature

Strany 14

FUNCTIONAL DESCRIPTION AND SPECIFICATIONS CHAPTER 2 Specifications SURETEST TORQUE CALIBRATION SYSTEM Specifications System Accuracy ±0.25% of readin

Strany 15

FUNCTIONAL DESCRIPTION AND SPECIFICATIONS CHAPTER 2 Power Requirements 100-230 VAC, 50-60 HZ, 50 W, automatic voltage selection. Fused at 3.15 A. E

Strany 16

FUNCTIONAL DESCRIPTION AND SPECIFICATIONS CHAPTER 2 SURETEST Transducer/Display Resolution mkg cmkg ft. lb. in. lb. in. oz. Nm dNm cN

Strany 17

SETUP AND PROGRAMMING CHAPTER 3 CHAPTER 3 SETUP AND PROGRAMMING CDI 5000-3 TORQUE CALIBRATION SYSTEM SETUP Figure 3-1: CDI 5000-3 Torque Tester/

Strany 18 - Rear Panel (Input/Output)

SETUP AND PROGRAMMING CHAPTER 3 Setting Up the CDI 5000-3 Torque Calibration System 1. Bolt the loader to a sturdy location. 2. Install Pivot tub

Strany 19 - F- PRINTER PORT (DB-9P)

SETUP AND PROGRAMMING CHAPTER 3 SURETEST Base Unit Controls Refer to the illustration below when performing the power-up and programming procedure

Strany 20 - SURETEST Transducers

SETUP AND PROGRAMMING CHAPTER 3 4-in-1 Transducer Installation When a 4-in-1 transducer is installed, the following is displayed: The

Strany 21 - Specifications

SETUP AND PROGRAMMING CHAPTER 3 Setup Programming Setting up Date and Time 1. Press (Setup). 2. Scroll Down (↓) to select Clock Adjus

Strany 22

SETUP AND PROGRAMMING CHAPTER 3 3. Press Enter (↵). The display reads: 4. Press --> (F5) or <-- (F6) to select High or Low

Strany 23 - SURETEST

SURETEST Base Unit Calibration 5-11 Gravitational Effects 5-14 Correction Factors on Test Weights 5-14 Gravitational Charts 5-1

Strany 24 - SETUP AND PROGRAMMING

SETUP AND PROGRAMMING CHAPTER 3 To Program AUTO CLEAR, STORE, or SEND: 1. Press (Setup). 2. Scroll Down (↓) to select Auto settings

Strany 25

SETUP AND PROGRAMMING CHAPTER 3 Clear Single Memory Location Use the procedure in this section to clear a single memory location. 1. Press

Strany 26 - SURETEST Base Unit Controls

SETUP AND PROGRAMMING CHAPTER 3 1. Press Setup 2. Scroll Down (↓) to select Edit Parameters 3. Press Enter (↵) the display read: 4. Press --&

Strany 27

TORQUE CALIBRATION SYSTEM SETUP CHAPTER 4 CHAPTER 4 CDI 5000-3 TORQUE CALIBRATION SYSTEM SETUP This chapter contains information on how to test,

Strany 28 - Setup Programming

TORQUE CALIBRATION SYSTEM SETUP CHAPTER 4 Dial and Bending Beam Torque Wrenches and Screwdrivers Be sure the SURETEST transducer is capable of handl

Strany 29 - Set-up AUTO Settings

TORQUE CALIBRATION SYSTEM SETUP CHAPTER 4 Adjustable or Preset “Click” Wrenches and Screwdrivers Be sure the SURETEST transducer is capable of handl

Strany 30 - DATA LIST Memory

TORQUE CALIBRATION SYSTEM SETUP CHAPTER 4 Testing Power Tools The dynamic torque characteristic of a power tool and the static torque applied when u

Strany 31

TORQUE CALIBRATION SYSTEM SETUP CHAPTER 4 Figure 4-1: Power Tool Test Setup A - Power Tool B - Joint Rate Simulator C - Transducer 7. Coupl

Strany 32

TORQUE CALIBRATION SYSTEM SETUP CHAPTER 4 tool clutch slips. Be careful not to add torque by turning the tool by hand. 14. Release the torque an

Strany 33 - CHAPTER 4

TORQUE CALIBRATION SYSTEM SETUP CHAPTER 4 Statistical Analysis The SURETEST Base Unit accumulates torque measurements in a data list. The list is c

Strany 34 - WARNING

Using this Manual This manual contains instructions for use and setup of the SURETEST 5000-3 Torque Calibration System. A table of contents and a t

Strany 35

TORQUE CALIBRATION SYSTEM SETUP CHAPTER 4 Printing Statistical Analysis 1. Press Data (F1) in select Transducer screen or (F2) in measurements mode

Strany 36 - Non-Impact Tools

TORQUE CALIBRATION SYSTEM SETUP CHAPTER 4 ** R E S U L T ** Data : 0010 Max : 254.89 in-lb Min : 251.49 in-lb Range : 3.4039 in-lb Mean : 253

Strany 37

TORQUE CALIBRATION SYSTEM SETUP CHAPTER 4 Displaying or Downloading Data List Torque measurements stored in the data list also include a date and t

Strany 38

TORQUE CALIBRATION SYSTEM SETUP CHAPTER 4 How to Use Analog Output (Rear Panel BNC Connector) Analog Output on the SURETEST provides a real time vo

Strany 39 - Statistical Analysis

CALIBRATION CHAPTER 5 CHAPTER 5 CALIBRATION The SURETEST Torque Calibration System is factory calibrated using precision torque test arms, ce

Strany 40 - SPC PRINT-OUT

CALIBRATION CHAPTER 5 Torque Under 250 ft. lb. Mount the calibration block at the center of the stand with two 1/2-13 socket head cap screws w

Strany 41

CALIBRATION CHAPTER 5 WARNING Always position the 40" arm over the front of the stand as shown. Never extend the test arm behind the sta

Strany 42 - Displaying Data List

CALIBRATION CHAPTER 5 The 4-in-1 transducer may also be mounted to the calibration stand, shown in Figure 5-1, using the standoff fixture and

Strany 43

CALIBRATION CHAPTER 5 Suggested Transducer Calibration Check Points, Bars, Hangers and Weights (Sheet 1 of 2) Part Bar Hanger

Strany 44 - CALIBRATION

CALIBRATION CHAPTER 5 Suggested Transducer Calibration Check Points, Bars, Hangers and Weights (Sheet 2 of 2) Part Bar Hanger

Strany 45 - Torque Over 250 ft. lb

DANGER Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury to the operator or to bystanders. W

Strany 46

CALIBRATION CHAPTER 5 Torque Calibrations SURETEST New Transducer Calibration Improper calibration can result in torque measurement errors

Strany 47 - Quick Check

CALIBRATION CHAPTER 5 6. Enter the following code into the display using the Cursor Keys: 5222 ( Left (←), Right (→) to select digit ; Up

Strany 48

CALIBRATION CHAPTER 5 Press Unit (F2) key and select the desired torque unit. 10. Using the Up (↑) and Down (↓) Cursor keys, enter the Ful

Strany 49

CALIBRATION CHAPTER 5 13. Press (Accept) to accept the calibration value (1st Cal point). Apply 20% Torque = 10 in. lb. 14. Press

Strany 50

CALIBRATION CHAPTER 5 22. All readings show minus sign (-). Press F1 twice to return to measurement mode. SURETEST Base Unit Calibrat

Strany 51 - Calibration CW:

CALIBRATION CHAPTER 5 4. Enter the following code into the display using the Cursor Keys: 5111. Then press (

Strany 52

CALIBRATION CHAPTER 5 Example: 08.0622 mV 7. Program the measured voltage into the SURETEST Indicator as demonstrated in the example,

Strany 53 - Calibration CCW:

CALIBRATION CHAPTER 5 Gravitational Effects Correction Factors on Test Weights Weights used in torque calibration are affected by their acce

Strany 54 - Equipment

CALIBRATION CHAPTER 5 Gravitational Charts The charts in this section are taken from CRC Handbook of Chemistry and Physics, 58th Edition.

Strany 55 - Calibrate tester

MANUAL LOADER CHAPTER 6 600TL - 600 ft. lb. Capacity Manual Loader The 600TL Manual Loader is designed as an integral component of the CDI 500

Strany 56

SAFETY INFORMATION Safety Information Important Safety Instructions This manual contains important safety and operating instructions for CDI 5000-3

Strany 57 - Gravitational Effects

MANUAL LOADER CHAPTER 6 Torque Tester/Calibrator Figure 6-1: Installation multiple transducers A- Quick release pin (Transducer) B- 4-in-1 T

Strany 58 - Gravitational Charts

MANUAL LOADER CHAPTER 6 Drive Adaptor A drive adaptor couples the wrench to the transducer. Low torque 2000 series transducers use an internal-

Strany 59 - Manual Loader

MANUAL LOADER CHAPTER 6 Figure 6-2 Set up for Dial indicating, Deflection Beam and Micro-Adjustable Torque Wrenches. 1- Transducer Mounting A

Strany 60 - IMPORTANT

MANUAL LOADER CHAPTER 6 Types of Loader Testing Torque Driver Testing An optional torque screwdriver testing kit, is available for use in testing

Strany 61

ACCESSORIES APPENDIX A Appendix A Accessories, included SURETEST 5000-3 Torque Calibration System Components Component Description 5000-ST SURE

Strany 62

ACCESSORIES APPENDIX A Appendix A Accessories, optional Component Description 2000-4-02 1/4" ext. drive 5 – 50 in. oz. Transducer

Strany 63 - Torque Driver Testing

ACCESSORIES APPENDIX A Component Description 2000-50-1 Cable, Indicator to PC 950-79 Foot Pedal Switch (Data Send foot swi

Strany 64 - Accessories, included

ACCESSORIES APPENDIX A Calibration Accessories Calibration of the SURETEST Indicator and 2000 series transducers is recommended at least every 1 y

Strany 65 - Accessories, optional

19220 San Jose Ave. City of Industry, CA 91748-1497 FORM 20-2100-CDI

Strany 66 - Component Description

SAFETY INFORMATION so the torque and load values are indicated on the display. The safety relays only work when the power is on. Flying parti

Strany 67 - Calibration Accessories

INTRODUCTION CHAPTER 1 CHAPTER 1 Introduction The SURETEST is a laboratory grade instrument that provides TORQUE measurements. Although desig

Strany 68 - 19220 San Jose Ave

INTRODUCTION CHAPTER 1 The SURETEST operates directly from any AC power line between 100 VAC to 230 VAC, 50–60 Hz without the need for switch sele